The BlueMaster AdBlue® storage and dispensing tanks have been specifically designed for the secure dispensing, management, and protection of AdBlue®. Manufactured with a double skin and fitted with an intelligent Tank Monitoring System (TMS), the BlueMaster AdBlue® Tank offers a long-term practical solution to liquid storage management.

Product Highlights

  • All BlueMaster tanks are double skinned for environmental protection and to safeguard against contamination
  • Innovative closed fluid path guarantees AdBlue purity and asset protection
  • Return on investment with onsite bulk storage means you can purchase larger volumes of AdBlue® saving you time and money
  • Quality product design, specification, and service with a 10-year guarantee*; ensuring absolute peace of mind
  • Trustworthy Service - with a 10-year guarantee*; ensuring absolute peace of mind

Technical Information

Dimensions
Capacity (l/gal)Length (mm)Width (mm)Height (mm)
2500 / 550246914601950
5000 / 110 (Vertical)285022502350
5000 / 1100 (Slimline)390011502340
9000 / 1980328024802950

Dimensions may vary within a small parameter due to manufacturing process variations or environmental conditions.

Specification
Description / CapacityTerminalStandardAdvancedPRO
Double Skinned Tank
Submersible Pump
2" Stainless Steel Dry Coupling Connection
Kingspan TMS

1” Stainless Steel Ball Valve terminated connection

Prepared for Kingspan WAP Telemetry
Hydrostatic Level Gauge

Automatic Dispensing Nozzle

Manual Pump Switch

3/4” EPDM Delivery Hose (6m on 2500L and 8m on 5000L Vertical & Slimline and 9000L)

Piusi Automatic Dispensing Nozzle with nozzle holder pump switch

Flowmeter

Light in Housing

Watchman Access Tank Managment System - Starter pack inc. 40 RFID Cards, 40 RFID Key Fobs and RFID Card Reader

Tank fitted with Kingspan WAP Telemetry
Elaflex ZVA Automatic Dispensing Nozzle

Elaflex LV ZVA Automatic Dispensing Nozzle

Hose Reel (not available on 2500L)

Inline Flowmeter

Pack of 10 RFID Cards & Key Fobs

Roaming SIM Card***

● = Standard accessories ○ = Optional accessories

Downloads

Data Sheets
BlueMaster Datasheet - GB/IE
BlueMaster Datasheet - GB/IE
pdf854kb
Data Sheets

Product Variants

  • BlueMaster® Terminal

    Our BlueMaster Terminal tank range has been designed to be incorporated into existing stand-alone dispensing and fuel management systems.

    Available Capacities
    2500L, 5000L, 9000L
    Terminal Features
    Kingspan Tank Monitoring System
    Terminal Features
    Submersible pump
    Terminal Features
    Prepared for Kingspan WAP Telemetry
  • BlueMaster® Standard

    The BlueMaster Standard Tank specification is an entry-level dispensing system with quality and functionality in mind.

    Available Capacities
    2500L, 5000L, 9000L
    Standard Features
    Double skinned tank
    Standard Features
    Automatic dispensing nozzle
    Standard Features
    Hydrostatic level gauge
  • BlueMaster® Advanced

    Manufactured with a double skin and fitted with an intelligent Tank Monitoring System (TMS), the BlueMaster Advanced AdBlue® Tank offers a long-term practical solution to liquid storage management.

    Available Capacities
    2500L, 5000L, 9000L
    Advanced Features
    Intelligent Tank Monitoring System
    Advanced Features
    Light in housing
    Advanced Features
    Flowmeter
  • BlueMaster® PRO

    The BlueMaster PRO AdBlue® storage solution, our highest specification of dispensing tank complete with the Watchman Access advanced fleet management system.

    Available Capacities
    2500L, 5000L, 9000L
    PRO Features
    Watchman Access Tank Management System
    PRO Features
    Starter pack inc. 40 RFID Cards, 40 RFID Key Fobs and RFID Card Reader
    PRO Features
    Prepared for Kingspan WAP Telemetry

Frequently Asked Questions

Can I transport AdBlue safely, and what are the options?

While AdBlue is not classified as a hazardous material (67/548/EEC), care should be taken when transporting Adblue due to it’s corrosive properties and reactions to certain compounds and materials such as mild steel, copper or aluminium as well as calcium and sodium hypochlorite.
 
Consider a dedicated transportation and dispensing tank such as BlueTruckMaster  as a portable solution.

What happens if you put AdBlue in your fuel tank?

AdBlue is a corrosive material and must not be added to the fuel tank. Damage can be caused to the tank and corresponding pipework if mixed. If in the unlikely event AdBlue is accidentally added to a fuel tank seek professional help to drain and flush the AdBlue solution from fuel tank.

Can AdBlue be stored outside?

AdBlue can be stored outside in a dedicated sealed tank, within a temperature range between 0°C and 30°C, and away from direct sunlight.

What is AdBlue?

AdBlue is a liquid solution of urea. When it meets a hot exhaust system it releases ammonia which is a catalyst to a chemical reaction that converts dangerous Nitrogen Oxides into two harmless products – water vapour and Nitrogen.

What is the best way to unload the tank?

Unloading must be carried out with the use of specialized equipment, such as a forklift or crane, slings and belts. To anchor slings, use special fastening points. It is important to make sure that the forks are sufficiently long. Sliding or rolling the tanks is prohibited. Never use projecting parts when lifting or sliding the tanks. Do not place any burdens on walls and roof.

How can we clean the nozzle?

AdBlue can crystalise in the nozzle. You can clean the nozzle by rinsing it with clean, warm water.

How to add power to the BlueMaster?

The tank is delivered without power supply line. A qualified engineer should connect a suitable 230V power line to junction box in the tank cabinet.

For BlueMasters with pumping equipment inside a cabinet, a hole must be drilled in the sidewall of the cabinet to connect the product to an external power source. It is essential that a grommet/gland be used in the sidewall to prevent water ingress into the cabinet and that the hole is located above the lowest edge of the door opening.

How to prime a pump?

230V pumps are self-priming pumps and should not require priming. If the pump fails to prime, please contact our customer service team.

Contact the Kingspan Team

Get in touch for more information on how we can help you with your project

Fuel Tank Servicing

As Service & Support specialists, we provide complete care to keep your fuel storage and dispensing tanks performing at their best.

Stay Connected with KNECT Pro

Monitor, manage, and optimise performance in real time with our advanced range of telemetry solutions. Our smart monitoring systems keep you connected to your Titan product - delivering instant insights, early alerts, and peace of mind from any location.

Main Navigation